Connectors and Pinouts

Connector Locations

Connector Placement

AL-3018 Connector Placement

Connector Name

Type

Description

J1, J2

Phoenix Contact MC 1,5/ 8-GF-3,81

DUT Interface

XJ1

55-pin Hard Metric type C

SLSC-12001 chassis interface

XJ2

110-pin Hard Metric type A

RTI Interface to external signals

J1 Connector Pinout

J1 Connector Pinout
Signal Descriptions

Signal Name

Reference

Direction

Description

CH<n>, DUT_NEG_A<n>

Output channel <n> – Negative on the output signal

CH<n>, INA<n>

Output channel <n> – Positive on the output signal

J2 Connector Pinout

J2 Connector Pinout
Signal Descriptions

Signal Name

Reference

Direction

Description

CH<n>, DUT_NEG_B<n>

Output channel <n> – Negative on the output signal

CH<n>, INB<n>

Output channel <n> – Positive on the output signal

XJ2 Connector Pinout for AL-3018

XJ2 Connector Pinout

Row

E

D

C

B

A

1

NC

NC

NC

NC

NC

2

NC

NC

NC

NC

NC

3

GND

GND

GND

GND

GND

4

NC

NC

NC

RTI_MOSI

RTI_CS

5

NC

NC

NC

RTI_MISO

RTI_SCLK

6

GND

GND

GND

GND

GND

7

NC

NC

NC

NC

NC

8

NC

NC

NC

NC

NC

9

GND

GND

GND

GND

GND

10

NC

NC

NC

NC

NC

11

NC

NC

NC

NC

NC

15

NC

NC

NC

NC

NC

16

NC

NC

NC

NC

NC

17

GND

GND

GND

GND

GND

18

NC

NC

NC

NC

NC

19

NC

NC

NC

NC

NC

20

GND

GND

GND

GND

GND

21

NC

NC

NC

NC

NC

22

NC

NC

NC

NC

NC

23

GND

GND

GND

GND

GND

24

NC

NC

NC

NC

NC

25

NC

NC

NC

NC

NC

Signal Descriptions

Signal Name

Reference

Direction

Description

DUT GND

Device Under Test Ground

RTI_CS

DUT GND

Output

DUT Channel – SPI Chip Select

RTI_SCLK

DUT GND

Output

DUT Channel – SPI Clock

RTI_MOSI

DUT GND

Output

DUT Channel – SPI MOSI

RTI_MISO

DUT GND

Output

DUT Channel – SPI MISO